Ajout doc
This commit is contained in:
parent
3bae86c4e0
commit
a56bf88fbe
139
HowtoPerccli.md
139
HowtoPerccli.md
|
@ -15,6 +15,19 @@ On télécharge `perccli` et on l'installe dans `/usr/local/sbin/perccli` :
|
|||
bsdtar -C /usr/local/sbin/ -'s|\./opt/MegaRAID/perccli/perccli64|perccli|' -xf- ./opt/MegaRAID/perccli/perccli64
|
||||
~~~
|
||||
|
||||
# Pierre de rosette
|
||||
|
||||
| PERCCLI | MegaCLI | Description |
|
||||
|------------------------------------+-----------------------------------------+-------------------|
|
||||
| `perccli /call show all` | `megacli -adpallinfo -aALL` | Adaptateurs |
|
||||
| `perccli /call/eall/sall show all` | `megacli -pdlist -aALL` | Disques physiques |
|
||||
| `perccli /call/vall show all` | `megacli -LDInfo -Lall -aALL` | Disques virtuels |
|
||||
| `perccli /call show events` | `megacli -AdpEventLog -GetEvents -aALL` | Logs |
|
||||
| `perccli /call show alilog` | `megacli -AdpAlILog -aALL` | NVRAM logs |
|
||||
|
||||
[Documentation de Broadcom](https://www.broadcom.com/support/knowledgebase/1211161499760/lsi-command-line-interface-cross-reference-megacli-vs-twcli-vs-s) traduisant les commandes `MegaCLI` en equivalant
|
||||
`StorCLI` (équivalant à `PERCCLI`).
|
||||
|
||||
# Explications
|
||||
|
||||
## Syntaxe de la ligne de commande
|
||||
|
@ -36,6 +49,38 @@ Par exemple pour avoir l'état du premier controleur (son index est donc 0) il f
|
|||
|
||||
Pour avoir une sortie en JSON d'une commande il suffit de la sufixer avec l'argument `J`. Par exemple pour avoir l'état du la batterie du premier controleur en JSON il faut executer `perccli /c0/bbu show J`.
|
||||
|
||||
## Exemple de sortie de la commande
|
||||
|
||||
```
|
||||
# perccli show
|
||||
CLI Version = 007.2313.0000.0000 Mar 07, 2023
|
||||
Operating system = Linux 6.1.0-16-amd64
|
||||
Status Code = 0
|
||||
Status = Success
|
||||
Description = None
|
||||
|
||||
Number of Controllers = 1
|
||||
Host Name = parbackup4bis
|
||||
Operating System = Linux 6.1.0-16-amd64
|
||||
|
||||
System Overview :
|
||||
===============
|
||||
|
||||
-------------------------------------------------------------------------
|
||||
Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
|
||||
-------------------------------------------------------------------------
|
||||
0 PERCH755Front 16 4 1 0 1 0 Opt On - N 0 Opt
|
||||
-------------------------------------------------------------------------
|
||||
|
||||
Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
|
||||
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
|
||||
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
|
||||
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
|
||||
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
|
||||
Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
|
||||
Chrg=Charging | MsngCbl=Cable Failure
|
||||
```
|
||||
|
||||
## Abréviations de la sortie standard
|
||||
|
||||
De nombreuses abréviations sont utilisées dans la sortie standard, en voici une **liste non exhaustive** :
|
||||
|
@ -215,3 +260,97 @@ Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
|
|||
Chrg=Charging | MsngCbl=Cable Failure
|
||||
~~~
|
||||
|
||||
# Mode d'emploi
|
||||
|
||||
|
||||
## Actions sur les disques physiques
|
||||
|
||||
|
||||
### Localiser un disque
|
||||
|
||||
Faire clignoter un disque :
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" start locate
|
||||
|
||||
Arrêter le clignotement d’un disque :
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" stop locate
|
||||
|
||||
|
||||
### Passer un disque en OFFLINE
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" set offline
|
||||
|
||||
|
||||
### Passer un disque en ONLINE
|
||||
|
||||
**!!! ATTENTION !!! ATTENTION !!! ATTENTION !!!**
|
||||
|
||||
L’erreur fatale à ne pas commettre lorsque vous constatez un disque en état
|
||||
Firmware state: Failed est de le forcer à revenir Online. En effet, cela
|
||||
force à repasser en mode RAID sans reconstruction et vous pouvez dire adieu
|
||||
à votre système de fichiers. NE FAITES DONC PAS :
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" set online
|
||||
|
||||
|
||||
### Passer un disque en missing
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" set online
|
||||
|
||||
Ça le sort du RAID.
|
||||
|
||||
|
||||
### Contrôler la rotation d’un disque rotatif
|
||||
|
||||
Stopper la rotation d’un disque, dans le but de le retirer :
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" spindown
|
||||
|
||||
Activer la rotation d’un disque :
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" spinup
|
||||
|
||||
|
||||
### Lancer la reconstruction d’un disque
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" start rebuild
|
||||
|
||||
|
||||
### Contrôler la reconstruction d’un disque
|
||||
|
||||
controler=0 ; enclosure=252 ; slot=0
|
||||
perccli "/c${controler}/e${enclosure}/s${slot}" show rebuild
|
||||
|
||||
|
||||
## Actions sur les disques virtuels
|
||||
|
||||
|
||||
### Extensions à chaud d’un disque virtuel
|
||||
|
||||
controler=0 ; virtual=239 ; size=1337
|
||||
perccli "/c${controler}/v${virtual}" expand "Size=$size"
|
||||
|
||||
|
||||
### Suivre l’extensions d’un disque virtuel
|
||||
|
||||
controler=0 ; virtual=239
|
||||
perccli "/c${controler}/v${virtual}" show expansion
|
||||
|
||||
|
||||
## Actions sur les controleurs disques
|
||||
|
||||
|
||||
### Accéder aux logs d’un controller
|
||||
|
||||
controler=0
|
||||
perccli "/c${controler}" show alilog
|
||||
|
||||
|
|
Loading…
Reference in a new issue