Update hp raid tool
This commit is contained in:
parent
ea93ffbf2b
commit
3e6b07c896
|
@ -16,7 +16,7 @@ Appuyer sur F9 au bon moment
|
||||||
# curl https://downloads.linux.hpe.com/SDR/hpePublicKey2048_key1.pub | apt-key add -
|
# curl https://downloads.linux.hpe.com/SDR/hpePublicKey2048_key1.pub | apt-key add -
|
||||||
|
|
||||||
# apt update
|
# apt update
|
||||||
# apt install hp-health hpssacli
|
# apt install ssacli
|
||||||
~~~
|
~~~
|
||||||
|
|
||||||
## Récupérer les informations des disques
|
## Récupérer les informations des disques
|
||||||
|
@ -24,7 +24,7 @@ Appuyer sur F9 au bon moment
|
||||||
Récapitulatif des disques virtuel et physiques :
|
Récapitulatif des disques virtuel et physiques :
|
||||||
|
|
||||||
~~~
|
~~~
|
||||||
# hpssacli ctrl all show config [detail]
|
# ssacli ctrl all show config [detail]
|
||||||
|
|
||||||
Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH8B0XM)
|
Smart Array P440ar in Slot 0 (Embedded) (sn: PDNLH0BRH8B0XM)
|
||||||
|
|
||||||
|
@ -52,7 +52,7 @@ On voit bien le tabeau RAID avec l'ID 0, et deux disques physiques qui composent
|
||||||
Ensuite, pour trouver le n° de série du disque, on prend sont ID de disque physique (1I:1:2) et on demande ses informations dans le tabeau RAID 0
|
Ensuite, pour trouver le n° de série du disque, on prend sont ID de disque physique (1I:1:2) et on demande ses informations dans le tabeau RAID 0
|
||||||
|
|
||||||
~~~
|
~~~
|
||||||
# hpssacli controller slot=0 physicaldrive 1I:1:2 show
|
# ssacli controller slot=0 physicaldrive 1I:1:2 show
|
||||||
|
|
||||||
Smart Array P440ar in Slot 0 (Embedded)
|
Smart Array P440ar in Slot 0 (Embedded)
|
||||||
|
|
||||||
|
|
Loading…
Reference in a new issue