- Documentation : [https://www.dell.com/support/kbdoc/en-uk/000177280/how-to-use-the-poweredge-raid-controller-perc-command-line-interface-cli-utility-to-manage-your-raid-controller]()
|
||
- Status de cette page : unstable / bullseye
|
||
|
||
[PERCCLI](https://www.dell.com/support/kbdoc/en-uk/000177280/how-to-use-the-poweredge-raid-controller-perc-command-line-interface-cli-utility-to-manage-your-raid-controller) est un utilitaire en ligne de commande permettant de gérer les controleurs RAID de Dell.
|
||
|
||
Dans notre usage PECCLI remplace [MegaCLI](InfosMegaCLI). PEERCLI est en réalité un rebranding du logiciel [StorCLI](https://docs.broadcom.com/doc/12352476) édité par Broadcom.
|
||
|
||
# Installation
|
||
|
||
On télécharge `perccli` et on l'installe dans `/usr/local/sbin/perccli` :
|
||
|
||
~~~(sh)
|
||
# curl -A notcurl -OL https://dl.dell.com/FOLDER09770976M/1/PERCCLI_7.2313.0_A14_Linux.tar.gz
|
||
# bsdtar -xOf PERCCLI_7.2313.0_A14_Linux.tar.gz PERCCLI_7.2313.0_A14_Linux/perccli-007.2313.0000.0000-1.noarch.rpm |
|
||
bsdtar -C /usr/local/sbin/ -'s|\./opt/MegaRAID/perccli/perccli64|perccli|' -xf- ./opt/MegaRAID/perccli/perccli64
|
||
~~~
|
||
|
||
# Pierre de rosette
|
||
|
||
| PERCCLI | MegaCLI | Description |
|
||
|------------------------------------+-----------------------------------------+-------------------|
|
||
| `perccli /call show all` | `megacli -adpallinfo -aALL` | Adaptateurs |
|
||
| `perccli /call/eall/sall show all` | `megacli -pdlist -aALL` | Disques physiques |
|
||
| `perccli /call/vall show all` | `megacli -LDInfo -Lall -aALL` | Disques virtuels |
|
||
| `perccli /call show events` | `megacli -AdpEventLog -GetEvents -aALL` | Logs |
|
||
| `perccli /call show alilog` | `megacli -AdpAlILog -aALL` | NVRAM logs |
|
||
|
||
[Documentation de Broadcom](https://www.broadcom.com/support/knowledgebase/1211161499760/lsi-command-line-interface-cross-reference-megacli-vs-twcli-vs-s) traduisant les commandes `MegaCLI` en equivalant
|
||
`StorCLI` (équivalant à `PERCCLI`).
|
||
|
||
# Explications
|
||
|
||
## Syntaxe de la ligne de commande
|
||
|
||
La commande `perccli` permet d'agir sur différent éléments des cartes RAID. Ci dessous se trouve la liste des premiers arguments supporté par la commande associé à leurs éléments, `X` correspond à l'index (commencant à 0) de cet élément :
|
||
|
||
- `/cX` : un controleur
|
||
- `/eX` : un ¿berceau? (*enclosure*)
|
||
- `/sX` : un emplacement (*slot*)
|
||
- `/vX` : un disque virtuel
|
||
- `/dX` : un groupe de disques
|
||
- `/fall` : la configuration externe (*foreign configuration*)
|
||
- `/pX` : un disque physique
|
||
- `/lnX` : une ligne (*Lane*)
|
||
- `/bbu` : la batterie (*battery backup unit*)
|
||
- `/cv` : le cache (*cache vault*)
|
||
|
||
Par exemple pour avoir l'état du premier controleur (son index est donc 0) il faut faire `perccli /c0 show`.
|
||
|
||
Pour avoir une sortie en JSON d'une commande il suffit de la sufixer avec l'argument `J`. Par exemple pour avoir l'état du la batterie du premier controleur en JSON il faut executer `perccli /c0/bbu show J`.
|
||
|
||
## Exemple de sortie de la commande
|
||
|
||
```
|
||
# perccli show
|
||
CLI Version = 007.2313.0000.0000 Mar 07, 2023
|
||
Operating system = Linux 6.1.0-16-amd64
|
||
Status Code = 0
|
||
Status = Success
|
||
Description = None
|
||
|
||
Number of Controllers = 1
|
||
Host Name = parbackup4bis
|
||
Operating System = Linux 6.1.0-16-amd64
|
||
|
||
System Overview :
|
||
===============
|
||
|
||
-------------------------------------------------------------------------
|
||
Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
|
||
-------------------------------------------------------------------------
|
||
0 PERCH755Front 16 4 1 0 1 0 Opt On - N 0 Opt
|
||
-------------------------------------------------------------------------
|
||
|
||
Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
|
||
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
|
||
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
|
||
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
|
||
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
|
||
Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
|
||
Chrg=Charging | MsngCbl=Cable Failure
|
||
```
|
||
|
||
## Abréviations de la sortie standard
|
||
|
||
De nombreuses abréviations sont utilisées dans la sortie standard, en voici une **liste non exhaustive** :
|
||
|
||
- ASOs : Advanced Software Options
|
||
- AWB : Always WriteBack
|
||
- AftrLD : Identify Freespace After LD
|
||
- AftrVD : Identify Freespace After VD
|
||
- Alms : Alarm count
|
||
- Arr : Array Index
|
||
- B : Blocked
|
||
- BBU : Battery backup unit/CV
|
||
- BT : Background Task Active
|
||
- C : Cached IO
|
||
- CBShld : Copyback Shielded
|
||
- CFShld : Configured shielded
|
||
- CO : Cache Offload
|
||
- CR : CacheCade(Read)
|
||
- CW : CacheCade(Read/Write)
|
||
- Cac : CacheCade
|
||
- CertProv : Certificate Provision mode
|
||
- Chrg : Charging
|
||
- Cl : Cluster
|
||
- Cmp : Compatible Profile
|
||
- Consist : Consistent
|
||
- Cpybck : CopyBack
|
||
- Ctl : Controller Index
|
||
- Curr : Current Profile
|
||
- DG : Drive Group
|
||
- DGs : Drive groups
|
||
- DHS : Dedicated Hot Spare
|
||
- DID : Device ID
|
||
- DNOpt : Array NotOptimal
|
||
- DS3 : Dimmer Switch 3
|
||
- DS : DimmerSwitch
|
||
- Dflt : Default Profile
|
||
- Dgd : Degraded
|
||
- Dgrd : Degraded
|
||
- EHS : Emergency Spare Drive
|
||
- EID : Enclosure Device ID
|
||
- F : Foreign
|
||
- FC : Flush Commands
|
||
- FP : Fast Path
|
||
- FSpace : Free Space Present
|
||
- FUA : Force Unit Access
|
||
- Fld : Failed
|
||
- FreSpc : Freespace available before expansion
|
||
- Frgn : Foreign
|
||
- GHS : Global Hotspare
|
||
- HA : High Availability
|
||
- HD : Hidden
|
||
- HSPShld : Hotspare shielded
|
||
- Hlth : Health
|
||
- IOPs : IO per second
|
||
- InDwdCnt : Invalid Dword Count
|
||
- Intf : Interface
|
||
- InvalDwdCnt : Invalid Dword count
|
||
- LosOfDwrdSynCnt : Loss of Dword synchronization count
|
||
- LsDwSyCnt : Loss of Dword system Count
|
||
- MD : Max Disks
|
||
- MaxAHCIDev : Maximum AHCI Devices
|
||
- MaxLD : Maximum Logical Drives
|
||
- MaxPCIeDev : Maximum PCIe Devices
|
||
- MaxPhyDrv : Maximum Physical Drives
|
||
- Med : Media Type
|
||
- Msng : Missing
|
||
- MsngCbl : Cable Failure
|
||
- MsngCbl : Missing Cable
|
||
- N : No
|
||
- NR : No Read Ahead
|
||
- NdAtn : Need Attention
|
||
- NoArrExp : Without Array Expansion
|
||
- OCE : Online Capacity Expansion
|
||
- OfLn : OffLine
|
||
- Offln : Offline
|
||
- Onln : Online
|
||
- Opt : Optimal
|
||
- Optl : Optimal
|
||
- Optm : Optimal Profile
|
||
- PD : Physical drive count
|
||
- PDC : Drive Cache
|
||
- PDC : PD Cache
|
||
- PDs : Physical drives
|
||
- PI : Protection Info
|
||
- PNO : Phy Number
|
||
- PS : Power Supply Count
|
||
- Pdgd : Partially degraded
|
||
- Pend : Pending Profile
|
||
- PhyNo : Phy Number
|
||
- PhyResetPrbCnt : Phy reset problem count
|
||
- ProdID : Product ID
|
||
- ProfID : Profile ID
|
||
- R : Read Ahead Always
|
||
- RC : Read Commands
|
||
- RF : Reduced Feature Set
|
||
- RO : Read Only
|
||
- RW : Read Write
|
||
- Rbld : Rebuild
|
||
- Re : Recovery
|
||
- Read RT : Average Read Response Time
|
||
- Rec : Recovery
|
||
- RepInProg : Repair in progress
|
||
- RnDiErCnt : Running Disparity Error Count
|
||
- Row : Row Index
|
||
- RungDispartyErrCnt : Running Disparity error count
|
||
- SED : Self Encrypting Drive
|
||
- SIM : SIM Count
|
||
- SR : Sectors Read
|
||
- SS : Safe Store
|
||
- SSHA : Single server High Availability
|
||
- SW-FUA : Sectors written with FUA
|
||
- SW : Sectors written
|
||
- Safe : Safe-mode boot
|
||
- SeSz : Sector Size
|
||
- SlotBP : Bays On Port
|
||
- Sntze : Sanitize
|
||
- Sp : Spun
|
||
- Span : Span Index
|
||
- T : TransitioTRANS=TransportReady
|
||
- TSs : Temperature Sensor count
|
||
- Temperature : Temperature in Degree Celsius
|
||
- Total RT : Average Total Response Time
|
||
- Type : Drive Type
|
||
- UBUnsp : UBad Unsupported
|
||
- UBad : Unconfigured Bad
|
||
- UGShld : UGood shielded
|
||
- UGUnsp : UGood Unsupported
|
||
- UGood : Unconfigured Good
|
||
- Unkwn : Unknown
|
||
- VD : Virtual Drive
|
||
- VDs : Virtual drives
|
||
- WB : WriteBack
|
||
- WBSup : Write Back Support
|
||
- WC-FUA : Write Commands with FUA
|
||
- WT : WriteThrough
|
||
- Write RT : Average Write Response Time
|
||
- X : Not Available/Not Installed
|
||
- Xfer Rate : Transfer Rate
|
||
- Y : Yes
|
||
- dflt : Default
|
||
- sCC : Scheduled
|
||
- sPR : Scheduled Patrol Read
|
||
- us : micro seconds
|
||
|
||
|
||
# Utilisation
|
||
|
||
## Avoir un aperçu des controlleurs RAID d'un systême
|
||
|
||
~~~
|
||
# perccli /c0/bbu show all
|
||
CLI Version = 007.2313.0000.0000 Mar 07, 2023
|
||
Operating system = Linux 5.10.0-24-amd64
|
||
Status Code = 0
|
||
Status = Success
|
||
Description = None
|
||
|
||
Number of Controllers = 1
|
||
Host Name = foo
|
||
Operating System = Linux 5.10.0-24-amd64
|
||
|
||
System Overview :
|
||
===============
|
||
|
||
---------------------------------------------------------------------------
|
||
Ctl Model Ports PDs DGs DNOpt VDs VNOpt BBU sPR DS EHS ASOs Hlth
|
||
---------------------------------------------------------------------------
|
||
0 PERCH750Adapter 8 10 4 0 4 0 Opt On - N 0 Opt
|
||
---------------------------------------------------------------------------
|
||
|
||
Ctl=Controller Index|DGs=Drive groups|VDs=Virtual drives|Fld=Failed
|
||
PDs=Physical drives|DNOpt=Array NotOptimal|VNOpt=VD NotOptimal|Opt=Optimal
|
||
Msng=Missing|Dgd=Degraded|NdAtn=Need Attention|Unkwn=Unknown
|
||
sPR=Scheduled Patrol Read|DS=DimmerSwitch|EHS=Emergency Spare Drive
|
||
Y=Yes|N=No|ASOs=Advanced Software Options|BBU=Battery backup unit/CV
|
||
Hlth=Health|Safe=Safe-mode boot|CertProv-Certificate Provision mode
|
||
Chrg=Charging | MsngCbl=Cable Failure
|
||
~~~
|
||
|
||
# Mode d'emploi
|
||
|
||
|
||
## Actions sur les disques physiques
|
||
|
||
|
||
### Localiser un disque
|
||
|
||
Faire clignoter un disque :
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" start locate
|
||
|
||
Arrêter le clignotement d’un disque :
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" stop locate
|
||
|
||
|
||
### Passer un disque en OFFLINE
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" set offline
|
||
|
||
|
||
### Passer un disque en ONLINE
|
||
|
||
**!!! ATTENTION !!! ATTENTION !!! ATTENTION !!!**
|
||
|
||
L’erreur fatale à ne pas commettre lorsque vous constatez un disque en état
|
||
Firmware state: Failed est de le forcer à revenir Online. En effet, cela
|
||
force à repasser en mode RAID sans reconstruction et vous pouvez dire adieu
|
||
à votre système de fichiers. NE FAITES DONC PAS :
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" set online
|
||
|
||
|
||
### Passer un disque en missing
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" set online
|
||
|
||
Ça le sort du RAID.
|
||
|
||
|
||
### Contrôler la rotation d’un disque rotatif
|
||
|
||
Stopper la rotation d’un disque, dans le but de le retirer :
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" spindown
|
||
|
||
Activer la rotation d’un disque :
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" spinup
|
||
|
||
|
||
### Lancer la reconstruction d’un disque
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" start rebuild
|
||
|
||
|
||
### Contrôler la reconstruction d’un disque
|
||
|
||
controler=0 ; enclosure=252 ; slot=0
|
||
perccli "/c${controler}/e${enclosure}/s${slot}" show rebuild
|
||
|
||
|
||
## Actions sur les disques virtuels
|
||
|
||
|
||
### Extensions à chaud d’un disque virtuel
|
||
|
||
controler=0 ; virtual=239 ; size=1337
|
||
perccli "/c${controler}/v${virtual}" expand "Size=$size"
|
||
|
||
|
||
### Suivre l’extensions d’un disque virtuel
|
||
|
||
controler=0 ; virtual=239
|
||
perccli "/c${controler}/v${virtual}" show expansion
|
||
|
||
|
||
## Actions sur les controleurs disques
|
||
|
||
|
||
### Accéder aux logs d’un controller
|
||
|
||
controler=0
|
||
perccli "/c${controler}" show alilog
|
||
|